Note that when determining the angle between h1 and x1, the rotation must be clockwise. A vector group is a method of specifying a threephase transformer or transformer bank method of connection and its angular displacement. Autotransformers do not provide galvanic isolation. But the transformer in which a part of windings is common to both primary and secondary is called auto transformer. Yna0d1 means star connected hv winding with neutral brought out, auto transformer with 0 degrees displacement. Three phase transformer consists of three sets of primary windings, one for each phase, and three sets of secondary windings wound on the same iron core. Training on vector groups of transformer presented by.
The naming convention popularly known as vector group of transformer was established by the international electrotechnical commission iec through iec 600761. Autotransformer with deltaconnected tertiary winding. This symbol indicates the winding connections and their relative phase displacement by means of a numerical index e. The capital letter a, b, c refers to the hv winding and the lower case a, b, c to the lv winding with a, b, c for. An autotransformer is a kind of transformer with only one winding, but one or more taps. Liggett group llc tobacco and new valley llc real estate, including douglas elliman. Transformer is the most important unit in an electrical distribution network. The transformer vector group is indicated on the name plate of transformer by the manufacturer. So it is utmost necessary to know how the inter connections to be made to. The harmonics in a transformer are present only in the transformer inrush current predominantly 2 nd harmonic content. Type tests are done mainly in a prototype unit not in all manufactured units in a lot.
The vector group of transformer is an essential property for successful parallel operation of transformers. The transformer vector group show the phase difference between the primary and secondary sides of the transformer. This cannot be avoided by selecting a tansformer with a particular vector group. I was lucky because the transformer ratio testset i used for the first couple of years in my career allowed me to make threephase connections, but it was really a singlephase tester and i had to change the connections one phase at time. According to iec764, the value of vector group can be 0,1,2,4,5,6,7,8,10,11. There is no technical difference between the one vector groups i. In auto transformer two windings are not only magnetically.
Pdf on mar 1, 2014, dalibor filipovicgrcic and others published modeling of threephase. Significance of vector group of transformer on the nameplate of threephase transformer vector group is printed as yy 0, dd 1 etc. For transformation ratio 2, the size of the auto transformer would be approximately 50% of the corresponding size of two winding transformer. Vector group test of power transformer electrical4u. On the basis of their connection, the vector group of the transformer is determined. Separate singlephase transformers can be used and externally interconnected to yield the same results as a 3phase unit. Contents hide 1 basic idea about transformer vector group 1. Primary and secondary must be star, with zero vector group phase shift. Dd0, dyn5, dyn11, yyn0, yd1, yd11, dz0, yz1 and yz11.
This was done in order to create a notation for threephase transformer winding configuration. Howard lorber has served as the companys president and chief executive officer since 1994. Autotransformer vector group cr4 discussion thread. The numerical index of the vector group comes from the clock hour gure the phase voltage hand 2u is at when the phase voltage hand of the high voltage winding 1u is at 12 oclock. What is meant by vector group for transformers and why is it important. Atharv deshpande, photography, electrical engineer. The autotransformer zero sequence impedance highly. Going counterclockwise between h1 and x1 can give wrong phase angle, and therefore wrong phase displacement number, which leads to wrong vector group and possibly to wrong test results. The three phase transformer is connected in various ways, i. A part of the winding is common to both primary and secondary sides. To perform transformers parallel operation without seeing the winding connection, the manufacturer mentions the transformers vector grouping to avoid accidental faults. An autotransformer connection with a tertiary delta winding.
Vector group is punched on the name plate based on the user requirement by the manufacture. Y star connection n neutral brought out a auto transformer 0 zero degrees d delta connection 1 30 degrees lag. An ordinary transformer consists of two windings called primary winding and secondary winding. The vector group indicates the phase difference between the primary and secondary sides. In other words the vector group of a transformer cannot aid in eliminating the harmonic content in its inrush current. Yna0d1 means star connected hv winding with neutral brought. Autotransformer iec vector group prc electrical 4 may 00. What is the use of transformer vector group dyn11 in tamil. The vector group of the protected autotransformer is ynautod5, thus the 220kv positive sequence, noload voltage component is in phase with 400kv positive sequence, noload voltage component. If you are replacing a transformer, use the same vector group for the new transformer, otherwise the existing vts and cts used for protection and metering will not work properly. Pdf modeling of threephase autotransformer for shortcircuit studies. Vector group of 3 winding transformer cr4 discussion thread. The determination of vector group of transformers is very important before. Three phase transformer vector grouping significance.
A vector group is the international electrotechnical commission iec method of categorizing the high voltage hv windings and low voltage lv. Transformer vector group the vector group test is importent test in the transformer testing. Together these make up the high voltage side of the transformer. Differential protection schemes for autotransformers abb group. It also determines the high voltage and low voltage windings arrangement of three phase transformers. Aim of vector group test is at site is to check if their is any damage in the windings during transportation and erection. What is the function of circulating current in two parallel transformers. Mainly, the type of transformer connections are divided in 4 below groups. These two windings are magnetically coupled and electrically isolated. The vector group of the protected autotransformer is ynautod5, thus the 220kv. Vector group test of transformerthe vector group of transformer is an essential property for successful parallel operation of transformers. How to draw transformer vector group connectionelectrical.
The determination of vector group of transformers is very important before connecting two or more transformers in parallel. The main contribution of this proposed model is to complete the set of sdomain models of. The clock method is used to produce the numerical index of. The systems phase sequence should be 1u, iv, 1w, or r, s and t the following are the most common threephase connections. Unit protection schemes for autotransformers can be either based on autotransformer ampereturn balance or based on first kirchhoff low between galvanically interconnected parts. The vector group indicates the phase difference between the primary and secondary sides, introduced due to that particular configuration of transformer windings connection. Hence every electrical power transformer must undergo through vector group test of transformer at factory site for ensuring the customer specified vector group of transformer. Three phase transformer winding configurations and. An autotransformer is generally used either for providing a second leg in a single phase system giving you 120240 vac from a single 120 vac line or to provide a 120 vac tap from a 240 vac. Description of vector group testing of vector group bangla tutorial for power point slide go to eee practical knowledge.
The vector group provides a simple way of indicating how the internal connections of a transformer are arranged. The zero sequence current must be eliminated from the. Conventional transformer of kva voltage ration 121. The unknown current vector i is calculated as a product of. All transformers are subjected to various tests at the manufacturer.
Understanding transformer vector groups transformer vector groups can be a difficult concept to understand. However, it differs in the way in which the primary and the secondary are interrelated. The power transformer connection type, the vector group and the subtraction of zero sequence currents onoff are setting parameters from these the differential protection calculates offline the matrix coefficients, which are then used in the online calculations. It consists of a capital and small letter plus a code number. The type tests of the transformer confirm the main and basic design criteria of a production lot.
Transformer connections from the same group can be. The phase sequence or the order in which the phases reach their. Department of electrical and electronics engineering. If one browses transformer sales literature, technical papers and books, and industry standards such as ieee c57. It should be noted that it is not possible to generate a zero phase shift between primary and secondary with a combination of delta and star windings. Threephase transformer connections and vector groups for. Auto transformer employs only single winding per phase as against two distinctly separate windings in a conventional transformer. The primary windings are connected in one of several. The connection of all the windings in a threephase transformer is indicated by a vector group symbol. The clock method is used to produce the numerical index of the vector group, with each hour representing 30.
The most common application of a deltadelta transformer is as tan isolation transformer for a. Measure the voltages in various combination on both side of the transformer hv lv. Explanation and vectorgroups schmidbauer transformers. Based on the windings connection, the vector group of the transformer is determined. You can use the zigzag transformer in two winding transformer applications, where you obtain voltage transformation and isolation with the zigzag feature. For each vector group need diffrent type of voltage combination to conform. Pdf transformer vector group test conditions k pandian. Therefore, for such differential protection scheme the transformer vector group shall be set as yy0. Vector group is an essential characteristics of 3 phase transformer.
We have a bank of autotransformer connected in three pase and has. Basic idea about transformer vector group in theory of a threephase transformer works like three equal and separated singlephase transformers working separately with three phase system with shared limbs. The vector group indicates the phase difference between the primary and secondary sides, introduced due to that particular configuration. The three phase transformer windings can be connected several ways. The transformer vector group is indicated on the name plate of. In a twowinding transformer, primary and secondary are only magnetically linked by a common core but are completely insulated from each other but in the case of an auto transformer. Transformer, voltage ratio, vector group, impedance, shortwhat is vector group. How do i draw vector group of transformer from winding connection. Working principle of autotransformer your electrical guide. The vector group transformer test is important for connecting two power transformer in parallel. Introduction to vector group the vector group marks the circuitry of windings and their phase position to each other. An auto transformer is similar to a two winding transformer but differ in the way the primary and secondary winding are interrelated. How to draw vector group of transformer from winding. On load condition, a part of the load current is obtained.
For each vector group need diffrent type of voltage combination to conform the vector group refer drawings. Applicationnote how to determine transformer vector group. They have electroconductive connection between input and output winding. Material made available on the website is proprietary and vector group. Vector group test of power transformer electrical mastar. The common portion of an autotransformer low voltage is the common winding, and the remainder is the series winding. An auto transformer is a transformer with only one winding wound on a laminated core. Fundamentals of shortcircuit protection for transformers. The working principle of autotransformer and construction is similar to that of conventional two winding transformers.
335 1440 948 1264 97 677 1347 1554 88 1556 1467 1474 416 154 686 1113 1193 336 29 1458 1372 949 176 441 1228 1543 46 776 1397 295 262 1608 1645 1033 1303 193 715 959 1064 799 827 698 52 1387 914 196